Author(s): Shweta Vinod Raul, Sunil P. Pawar, Sunila A. Patil

Email(s): Shwetaraul10@gmail.com

DOI: 10.52711/2231-5675.2026.00033   

Address: Shweta Vinod Raul, Sunil P. Pawar, Sunila A. Patil
P.S.G.V.P Mandal's College of Pharmacy Shahada, Dist. Nandurbar, Maharashtra, India.
*Corresponding Author

Published In:   Volume - 16,      Issue - 3,     Year - 2026


ABSTRACT:
Fesoterodine, a relatively new antimuscarinic medication used to treat overactive bladder, has undergone extensive testing in the elderly and has been linked to a notable improvement in both quality of life and disease-related outcomes. In this older patient population, fesoterodine also seems to be well tolerated. For many elderly persons, overactive bladder is a prevalent and problematic condition. In late 2008, the US Food and Drug use approved fesoterodine, a nonselective muscarinic-receptor antagonist, for once-daily oral use in the treatment of OAB to alleviate the symptoms of urgency, frequency, and incontinence. The prevalence of overactive bladder (OAB), a chronic illness that affects both men and women, rises with age. The mainstay of OAB treatment is antimuscarinics. The evidence for fesoterodine in older adults is covered in this review. There are numerous approaches for the examination of Fesoterodine HCI, according to the literature, so we compiled them all into a single review. High Performance Liquid Chromatography (HPLC), High Performance Thin Layer Chromatography (HPTLC), RP-HPLC, and the Stability Indicating assay method were used to monitor fesoterodine HCL for development and validation. The main emphasis is on chromatographic techniques, especially High-Performance Liquid Chromatography (HPLC), which is still the most popular method because of its precision, accuracy, and robustness. Critical validation parameters, such as linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ), are examined in compliance with the guidelines established by the International Council for Harmonization (ICH) and other regulatory authorities. A number of important factors involved in method development, such as column type, detection wavelength, and mobile phase compositions, are thoroughly discussed.


Cite this article:
Shweta Vinod Raul, Sunil P. Pawar, Sunila A. Patil. A Review on Analytical Techniques for Fesoterodinefumarate. Asian Journal of Pharmaceutical Analysis. 2026; 16(3):219-3. doi: 10.52711/2231-5675.2026.00033

Cite(Electronic):
Shweta Vinod Raul, Sunil P. Pawar, Sunila A. Patil. A Review on Analytical Techniques for Fesoterodinefumarate. Asian Journal of Pharmaceutical Analysis. 2026; 16(3):219-3. doi: 10.52711/2231-5675.2026.00033   Available on: https://ajpaonline.com/AbstractView.aspx?PID=2026-16-3-9


REFERENCES:
1.    Abrams P, Cardozo L, Fall M, et al, for the Standardisation Sub-Committee of the International Continence   Society. The standardisation of termin ology in lower urinary tract function: Report From the standardisation sub-committee of the International Conti nence Society. Urology. 2003; 6 1: 37-49.
2.    Haylen BT, de Ridder D, Freeman RM et al. Association (IUGA)/ International Continence Society (ICS) joint report on the terminology for female pelvic floor 1 An International Urogynecological dysfunction. Neurourol. Urodyn. 2010; 29(1): 4-20
3.    Stewart WF, Van Rooyen JB, Cundiff GW et al. Prevalence and burden of overactive bladder in the United States. World J. Urol. 2003; 20(6): 327-336.
4.    Hashim H, Abrams P. Pharmacological management of women with mixed urinary incontinence. Drugs. 2006; 66:591- 606.
5.    Rosenblum N. Will the evolution of overactive bladder delivery systems increase patient compliance? Rev Urol. 2009; 11: 45- 51.   
6.    McKeage K, Keating GM. Fesoterodine. Drugs. 2009; 69: 731-738  
7.    Ellsworth P, Berriman S), Brodsky M. Fesoterodine: A new agent for treating overactive bladder. A m J Manag Care. 2009; 15(SuppI 4): S1l5- S117.
8.    Simon HU, Malhotra B. The pharmacokinetic profile of fesoterodine: Similarities and differences to tolterodine. Swiss Med Wkly. 2009; 139: 146-151.
9.    Malhotra B, Sachse R, Wood N. Evaluation of drug-drug interactions with fesoterodine. Eur JClin Pharmacol. 2009; 65: 551-560.
10.    European Medicines Agency. Toviaz 4 mg prolonged-release tablets: Summary of productCharacteristics. Hrtp: IIwww.ema.europa.eu/docs/en_GB/document_library/EPAR_-_ProduceInformation/human/000723/WC500040178.pdf. Accessed July 23, 2009.
11.    Reddy V.P, Rajan T.V.S, Kumar A. N, A Review on Analytical Method Validation. Int J Rev Life Sci. 1: 141-144.
12.    Chinmaya K. S, Muvvala S., Nalini K. S., Validation of Analytical Methods: A Review, International Journal of Chromatography And Separation Techniques. 2018;1
13.    Vidushi Y, Meenakshi B. A review on HPLC method development and validation. Res J Life Sci. 2017; 2(6): 178.
14.    Ramole Rina, Mohini Baile*, Ashish Jain Department of Quality Assurance, Shri. D. D. Vispute College of Pharmacy and Research Center, Mumbai, India.
15.    Hokanson GC. A life cycle approach to the validation of analytical methods during pharmaceutical product development part I: The initial validation process. Pharm.Tech. 1994; 118-30.
16.    Sahoo NK, Sahu M, Veerachamy A, Lalitha BV, MoharanaAK, SahooCK.Quantification and validation of simvastatin and ezetimibe in bulk drugs and combined dosage form by reverse phase liquid chromatographic method (RPLC). Pharm.Methods 2015; 6(2): 115-9.
17.    Sahoo NK, SahuM, AlagarsamyV, SrividyaB, SahooCK.Current status of two-dimensional gel validation of assay indicating method development of imatinib in bulk and its capsule dosage form by liquid chromatography. Ann. Chromatogr Sep. Tech. 2015; 1(2): 1010.
18.    MoharanaAK, BanerjeeM, SahooCK, SahooNK. Development and validation of RP-HPLC method for mesalamine. Asian J. of Pharmaceutical and Clinical Research 2011; 4(Suppl.2): 71-73.
19.    Renger B, Jehle H, Fischer M, Funk W.Validation of analytical procedures in pharmaceutical analytical chemistry: HPTLC assay of theophylline in an effervescent tablet. J. Planar. Chrom.1995; 8: 269-78 
20.    Sahoo NK, Sahu M, Praneeth P, Manjeera PSK, Lavanya K. Degradation motitoring method development and validation of spectophotometric estimation of atrovastatin calcium in bulk and tablet formulation. J. of Pharm. Biomed. Sci. 2013; 33(33): 1551-1557.
21.    Patel NK, Subhaiah G, Shah H, Mohan M, Shrivastav SP. Rapid LC-ESI-MS-MS method for the simultaneous determination of clopidogrel and its carboxylic acid metabolite in human plasma. J. Chromatogr. Sci. 2008; 46: 867-875.
22.    Vander HY, Nijhuis A, Verbeke JS, VandegtnsteBG, MassartDL.Guidance for robustness/ruggedness test in method validation. J Pharm Biomed Anal. 2009; 24: 723-53.
23.    Sahoo NK, Sahu M, Podilapu S, Rao JNI, Rani SN, Ghosh GK. Validation of assay for bulk clopidogrel and for some tablet forms by reverse phase high performance liquid chromatography of Taibah University for Science. 2014; 8: 331-336.
24.    Saldanha TC.de Araújo MU, Neto BB, Chame HC. (Simultaneous analysis of Co2+, Cu2+ Mn2+, Ni2+ and Zn2+ in the ultraviolet region Using 4-(pyridil-2azo) resorcinol and Multivariate calibration). Anal Lett. 2000; 33(6): 1187-1202.
25.    Bosch Ojeda C, Sanchez Rojas F. Recent applications in derivative ultraviolet/visible Absorption spectrophotometry: 2009 2011. Microchem J. 2013; 106:1-16. Doi 10.1016/jmicroc. 2012.05.012.
26.    Kealey, D., & Haines, P. J. (2002). BIOS Instant Notes in Analytical Chemistry. Garland Science.
27.    Kazakevich, Yuri; LoBrutto, Rosario, eds. (2007). HPLC for pharmaceutical scientists. Hoboken, NJ: Wiley-Interscience. ISBN 978-0-471-68162-5.
28.    Rathod, R.H., Chaudhari, S.R., Patil, A.S. et al. Ultra-high-performance liquid Chromatography-MS/MS (UHPLC-MS/MS) in practice: analysis of drugs and pharmaceutical formulations. Futur J Pharm Sci. 2019; 5: 6.
29.    Snyder, L. R., Kirkland, J. J., & Dolan, J. W. (2011). Introduction to Modern Liquid Chromatography (3rd ed.). Wiley.
30.    D Sangeetha, Nitin Kumar and L Kalyanraman, Stability indicating RP HPLC Method for the estimation of process related Impurities and Degradation products in Fesoterodine Fumarate Journal of Chromatographic Science. 2021; 59(2): 154-164 doi: 10.1093/chrumsci/bmaa090 Advance Access Publication Date: 14 November 2020
31.    A. P Rajput and Manohar C. Sonanis Stability Indicating HPLC Method for the Enantiomeric Separation of Fesoterodine Fumarate in Drug Product and Drug Substance Using Chiral Stationary Phase.Journal of Chemical and Pharmaceutical Research, 2012; 4(9): 4127-4133.
32.    B.V.Rami Reddy, B.S.Reddy, M.Sravan Kumar' and C.Rambabu A Validated stability indicating HPLC Assy Method for Determination of Fesoterodine Fumarate Rasayan J. Chem. 2012; 5(2): 239-245http://www.rasayanjournal.com

Asian Journal of Pharmaceutical Analysis (AJPA) is an international, peer-reviewed journal, devoted to pharmaceutical analysis...... Read more >>>

RNI: Not Available                     
DOI: 10.5958/2231–5675 


Recent Articles




Tags