Author(s):
O.S.S. Chandana, R. Ravichandra Babu
Email(s):
osschandana@gmail.com
DOI:
10.5958/2231-5675.2017.00031.X
Address:
O.S.S. Chandana1, R. Ravichandra Babu2
1, 2Department of Chemistry, Institute of science, GITAM University, Visakhapatnam, Andhra Pradesh, India
*Corresponding Author
Published In:
Volume - 7,
Issue - 3,
Year - 2017
ABSTRACT:
A simple, fast, accurate and specific reverse phase high pressure liquid chromatographic (HPLC) method has been developed for simultaneous determination of Sildenafil base and its impurities in the Sildenafil Tartrate (API). The method was developed by reversed phase chromatography equipped with C18 (100 ? 4.6 nm ? 5.0 nm) column using mobile phase of (0.1%) formic acid and methanol (30:70 ratio) with a flow rate of 0.5 ml/min with ultraviolet detector configured at 290nm. The method was validated as per ICH guidelines.
Cite this article:
O.S.S. Chandana, R. Ravichandra Babu. Stability Indicating High Performance Liquid Chromatographic Assay for the Determination of Sildenafil Tartrate. Asian J. Pharm. Ana. 2017; 7(3): 196-200. doi: 10.5958/2231-5675.2017.00031.X
Cite(Electronic):
O.S.S. Chandana, R. Ravichandra Babu. Stability Indicating High Performance Liquid Chromatographic Assay for the Determination of Sildenafil Tartrate. Asian J. Pharm. Ana. 2017; 7(3): 196-200. doi: 10.5958/2231-5675.2017.00031.X Available on: https://ajpaonline.com/AbstractView.aspx?PID=2017-7-3-11