Author(s): J. Ramesh Babu, J. Suhasini, S. Vidyadhara

Email(s): ramesh.janga11@gmail.com

DOI: 10.5958/2231-5675.2018.00002.9   

Address: J. Ramesh Babu, J. Suhasini, S. Vidyadhara Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chandramoulipuram, Chowdavaram, Guntur.(A.P.), India.
*Corresponding Author

Published In:   Volume - 8,      Issue - 1,     Year - 2018


ABSTRACT:
There are only few published reports on determination of residual solvents in the analytical method development and there exists no detailed guidelines. Residual solvents from the process in the manufacturing of pharmaceuticals are hazardous and cause serious problems, so must be removed. This is much effort in this work is focused on the determination of analytical method for the determination of residual solvents. Bendamustine hydrochloride pure drug, various solvents, Shimadzu GC-2010 with head space auto injector and AOC – 5000 with head space auto injector were used. The method development based on residual solvent properties and many trails conducted on conditions like column selection, carrier gas flow, oven temperature and diluent. A simple HS-GC method for the determination of residual solvents in Bendamustine hydrochloride using helium as the carrier gas at 3.0mL/min with DB-624 (30.0 meters X 0.53 mm ID, 3.0µm d.f. capillary) as column using FID as detector was developed. The developed method was validated and parameters were to be found within the limits of USP. The retention time for residual solvents individually and in spiked standard solution was determined. The %RSD for six injections should be NMT15%. The percentage recovery ranges from 84.57-118.86%. The correlation coefficient was R2 = 0.999. The method was validated for repeatability, linearity, limit of detection, limit of quantification and recovery according to the International Conference on Harmonization guidelines. The method validation results indicate that the method is accurate, precise, linear and sensitive for solvents assessed. Excellent results were obtained, within the globally accepted validation reference values, particularly taking into account the low concentration levels investigated.


Cite this article:
J. Ramesh Babu, J. Suhasini, S. Vidyadhara. Residual Solvents in Bendamustine Hydrochloride By Headspace Chromatography. Asian J. Pharm. Ana. 2018; 8(1):07-12. doi: 10.5958/2231-5675.2018.00002.9

Cite(Electronic):
J. Ramesh Babu, J. Suhasini, S. Vidyadhara. Residual Solvents in Bendamustine Hydrochloride By Headspace Chromatography. Asian J. Pharm. Ana. 2018; 8(1):07-12. doi: 10.5958/2231-5675.2018.00002.9   Available on: https://ajpaonline.com/AbstractView.aspx?PID=2018-8-1-2


Recomonded Articles:

Author(s): Sushil D. Patil, Sunil V. Amurutkar, C.D. Upasani

DOI: 10.5958/2231-5675.2016.00030.2         Access: Open Access Read More

Author(s): Pankaj Bhamare, Rupal Dubey, Neeraj Upmanyu, Pothuvan Umadoss

DOI: 10.5958/2231-5675.2021.00001.6         Access: Open Access Read More

Author(s): K. Pramod, Shahid H. Ansari, Javed Ali

DOI:         Access: Open Access Read More

Author(s): Yogita R. Indalkar, Aloorkar N.H.

DOI: 10.5958/2231-5675.2015.00028.9         Access: Open Access Read More

Author(s): Sushil D. Patil, Sayali K. Chaure, Maswood Ahmed Hafizur Rahman, Prajkta U. Varpe, Sanjay Kshirsagar.

DOI: 10.5958/2231-5675.2017.00004.7         Access: Open Access Read More

Author(s): Pinaz A. Kasad, K.S. Muralikrishna

DOI:         Access: Open Access Read More

Author(s): Sri Lakshmi D, Jane T Jacob, Srinivasa Sastry D, Satyanarayana D

DOI: 10.5958/2231-5675.2017.00005.9         Access: Open Access Read More

Author(s): Saroj Kumar Raul, Gopal Krishna Padhy, Pramudula Ramya Krishna, Boddu Uma Madhu Priya

DOI:         Access: Open Access Read More

Author(s): Mansi J. Chaudhari, Suraj R. Chaudhari, Shailesh S. Chalikwar, Atul A. Shirkhedkar

DOI: 10.5958/2231-5675.2018.00008.X         Access: Open Access Read More

Asian Journal of Pharmaceutical Analysis (AJPA) is an international, peer-reviewed journal, devoted to pharmaceutical analysis...... Read more >>>

RNI: Not Available                     
DOI: 10.5958/2231–5675 


Recent Articles




Tags